MAC地址表实验
动态AMC地址
#通过源mac地址表学习
dis mac-address
MAC address table of slot 0:
-------------------------------------------------------------------------------
MAC Address VLAN/ PEVLAN CEVLAN Port Type LSP/LSR-ID
VSI/SI MAC-Tunnel
-------------------------------------------------------------------------------
5489-9876-4d77 1 - - GE0/0/1 dynamic 0/-
5489-986b-2f23 1 - - GE0/0/2 dynamic 0/-
5489-98bd-3d3f 1 - - GE0/0/3 dynamic 0/-
5489-982f-1b13 1 - - GE0/0/4 dynamic 0/-
-------------------------------------------------------------------------------
Total matching items on slot 0 displayed = 4
#在系统复位、接口板热插拔或接口板复位后,动态表项会丢失。
静态MAC地址
#手动配置
[Huawei]mac-address static 5489-986b-2f23 GigabitEthernet 0/0/2 vlan 1
[Huawei]dis mac-address
MAC address table of slot 0:
-------------------------------------------------------------------------------
MAC Address VLAN/ PEVLAN CEVLAN Port Type LSP/LSR-ID
VSI/SI MAC-Tunnel
-------------------------------------------------------------------------------
5489-986b-2f23 1 - - GE0/0/2 static -
-------------------------------------------------------------------------------
Total matching items on slot 0 displayed = 1
MAC address table of slot 0:
-------------------------------------------------------------------------------
MAC Address VLAN/ PEVLAN CEVLAN Port Type LSP/LSR-ID
VSI/SI MAC-Tunnel
-------------------------------------------------------------------------------
5489-9876-4d77 1 - - GE0/0/1 dynamic 0/-
5489-98bd-3d3f 1 - - GE0/0/3 dynamic 0/-
5489-982f-1b13 1 - - GE0/0/4 dynamic 0/-
-------------------------------------------------------------------------------
Total matching items on slot 0 displayed = 3
黑洞表项
[Huawei]mac-address blackhole 5489-98bd-3d3f vlan 1
[Huawei]dis mac-address
MAC address table of slot 0:
-------------------------------------------------------------------------------
MAC Address VLAN/ PEVLAN CEVLAN Port Type LSP/LSR-ID
VSI/SI MAC-Tunnel
-------------------------------------------------------------------------------
5489-986b-2f23 1 - - GE0/0/2 static -
5489-98bd-3d3f 1 - - - blackhole -
-------------------------------------------------------------------------------
Total matching items on slot 0 displayed = 2
MAC address table of slot 0:
-------------------------------------------------------------------------------
MAC Address VLAN/ PEVLAN CEVLAN Port Type LSP/LSR-ID
VSI/SI MAC-Tunnel
-------------------------------------------------------------------------------
5489-982f-1b13 1 - - GE0/0/4 dynamic 0/-
5489-9876-4d77 1 - - GE0/0/1 dynamic 0/-
-------------------------------------------------------------------------------
Total matching items on slot 0 displayed = 2